Gain Measurement - メーカー・企業と製品の一覧

Gain Measurementの製品一覧

1~2 件を表示 / 全 2 件

表示件数

Antenna gain measurement using the standard antenna method.

[Application Example] We will introduce a method for measuring antenna gain using the standard antenna method with a radio wave dark box and a spectrum analyzer.

【Product Introduction】 ■ Anechoic Chamber / Shield Box Low cost, lightweight, and short delivery time! High-quality, reliable, and cost-effective anechoic chambers and shield boxes provided by a measurement instrument manufacturer. ■ Spectrum Analyzer MSA438TG Model with Tracking Generator - Measurement Frequency: 50kHz to 3.3GHz ■ Signal Analyzer MSA538TG Model with Tracking Generator - Measurement Frequency: 20kHz to 3.3GHz To evaluate antenna gain, a calibrated standard antenna or an anechoic chamber is typically required, but using a spectrum analyzer with a tracking generator and an anechoic chamber allows for simple evaluation. - The gain of the EUT is determined by comparison with a reference antenna (an antenna with known gain). - The measurement environment is the same as for radiation pattern measurements, conducted in an anechoic chamber (shield box). - Primarily, dipole and log-periodic antennas are used in the MHz range, while horn antennas are used in the GHz range.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Antenna gain measurement using a tracking generator.

[Application Example] A tool that allows for easy and convenient antenna measurement at your fingertips.

We will introduce a case study on how to easily measure antenna gain characteristics using a handheld spectrum analyzer with a tracking generator. To evaluate antenna gain, calibrated standard antennas or anechoic chambers are typically required, but by using the MSA438TG and an anechoic box, it can be evaluated simply. The measurement procedure is as follows: 【Measurement Procedure】 (1) Prepare two sets of the antenna to be tested and install them at a fixed distance within the anechoic box. (2) Set the center frequency and span of the spectrum analyzer to match the desired frequency band. (3) Directly connect the tracking generator output and the spectrum analyzer signal input within the anechoic box and normalize. (4) Connect the output of the tracking generator to Antenna 1. (5) Connect the signal input of the spectrum analyzer to Antenna 2. (6) Execute the measurement. *For more details, please refer to the PDF document or feel free to contact us.

  • others

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録